Propane Torpedo vs. 240V Electric vs. Mini-Split: The Real Cost of Heating a Garage Woodshop

Caleb "Cal" Rodriguez
November 28, 2026
Snowy garage workshop with propane tank, space heater, and workbench under a lamp

Propane Torpedo vs. 240V Electric vs. Mini-Split: The Real Cost of Heating a Garage Woodshop - A step into the workshop.

NEW FREE TOOL

Stop Wasting Wood

Generate clear cut diagrams instantly with our new Cutlist Optimizer. Plan your cuts to make your next build easier.

The first cold snap hits and every guy with a table saw in his garage goes shopping for the same thing: the cheapest heater that will make the shop tolerable. That's the wrong order of operations. The cheap heater is a decision you'll keep paying for every time the thermometer drops, and it may be quietly working against your cast iron while it does it.

I'm not going to pretend the math is simple, because it depends on where you live in a way that actually flips the ranking. But it's not hard either, and once you run it for your shop the answer gets a lot clearer.

The Load Is the Whole Argument

A shop heater needs to be sized from a heat-loss calculation, not from floor area. ToolGrit's shop-heater sizing calculator breaks it down the way a load calc should: conduction through walls and ceiling, slab-edge loss, and air infiltration, all driven by the temperature difference between inside and outside. That's the number that matters most — desired indoor temp minus your outdoor design temp.

A garage shop is basically three heat-loss problems stacked together: the slab, the overhead door, and air leaking through every seam the mice found first. If your door closes with a visible gap and the slab is uninsulated, you can buy all the BTUs you want and watch them leave.

One thing to be honest about: ToolGrit describes its own output as "a starting load" for the heater conversation, not a Manual J or ASHRAE calculation, and points to the ASHRAE Handbook and ACCA Manual J as the real references. It doesn't size venting, gas pipe, or electrical circuits either. Treat it as a starting estimate. Also note it doesn't account for warm-up time or thermal mass, which in a cold slab shop is exactly the thing you feel on Saturday morning.

Cost per Million BTU Is the Only Number That Matters

Now the part the heater box doesn't tell you. Every fuel type can be converted to cost per delivered million BTU. Here's the arithmetic, using U.S. Energy Information Administration rates for September 2026 electricity and the week of 11/23/26 for propane.

Electricity has a fixed conversion: EIA lists 1 kilowatthour at 3,412 Btu. A 240V resistance heater delivers that 3,412 Btu per kWh essentially in full, because resistance heating is about 100% efficient at the point of use. Per million BTU, that's 1,000,000 ÷ 3,412, or about 293 kWh. At the U.S. average residential rate of 18.17 cents per kWh, that's roughly $53 per million BTU. In Maine at 31.29 cents, call it $91. In North Dakota at 14.29 cents, about $42.

Propane is denser. AmeriGas lists a gallon at 91,452 Btu, so a million BTU is roughly 11 gallons. But the spread is brutal: Iowa at $1.790/gal comes to roughly $20, while Connecticut at $4.309/gal lands near $47. If your propane appliance is vented at 80% efficiency — the Modine Hot Dawg HD45AS0111 is listed at 80%, the Martin direct-vent wall heater at 77%, per PickHVAC — divide the result by 0.8 and the U.S. average becomes about $38.

Here's the crossover the angle demands. Use the EIA rates and resistance heat at North Dakota's 14.29 cents still costs about $42, worse than propane at the Midwest average of $2.297 (about $25). But resistance at those cheap-power rates beats propane in Connecticut at $4.309, where propane runs about $47. Resistance heat only wins where your power is cheap and your propane is expensive. Everywhere else it loses, usually badly.

Heat pumps don't play by the 3,412 ceiling because they move heat instead of making it. ENERGY STAR defines COP as delivered heating rate divided by electrical energy consumed, and HSPF2 in Btu per watt-hour is directly comparable to COP — 1 watt-hour equals 3.412 Btu. A heat pump rated 8.5 HSPF2 is doing roughly 8.5 Btu per watt-hour. At COP 3 and 18.17 cents, that's about $18 per million BTU. At the ENERGY STAR cold-climate floor of COP 1.75 at 5°F, it's about $30. Still better than resistance, but no longer a 3:1 story.

I need to be clear about what this math is: fuel cost only. It leaves out purchase price, installation, venting, tank rental, electrical work, and maintenance. Those figures weren't verified in my research and I won't make them up. But four numbers tell the story. At U.S. average rates, resistance runs about $53 per million BTU, propane about $31, a heat pump at COP 3 about $18. The cheapest heater on the shelf is the most expensive one to run.

The Hidden Cost Is Water

This is where the torpedo argument falls apart, and it has nothing to do with the fuel bill.

Burning propane produces water and carbon dioxide as exhaust — that's the chemistry, per AmeriGas. A vent-free torpedo puts all of it in your shop. Empire, a gas appliance manufacturer, estimates roughly 30 milliliters of water per 1,000 Btu of hourly gas input, which HVACLens reports as about 0.9 liters an hour at 30,000 Btu/h.

Watch what that does overnight. The shop cools down while the moisture is still in the air, surfaces drop toward the dew point, and water condenses on cold metal. That's standard psychrometrics, not a citation — but it's exactly why cast iron tables and machined ways start showing rust blooms you can't explain in spring. You heated the shop and humidified it at the same time. Then the heat stopped and the water stayed.

You know the rest. Empire's own manual recommends supplemental use rather than whole-house heating, suggests watching for window condensation and recording humidity, and warns not to size capacity from floor area alone. The EPA identifies carbon monoxide, nitrogen dioxide, and particles as major pollutants from indoor combustion including unvented gas heaters, with children and asthmatics most vulnerable to NO₂. An oxygen-depletion sensor is not a CO alarm. The CPSC says never run an unvented fuel-burning appliance in a room where people are sleeping — which is worth remembering if you ever lose track of time out there.

Three Technologies, Three Humidity Answers

The 240V electric unit adds no moisture because there's no fuel and no flue. It doesn't remove moisture either — it just keeps surfaces above the dew point while it's running, and when it stops, the water's still there. Don't let anybody tell you an electric heater dehumidifies, because it doesn't.

A mini-split in heating mode produces no combustion moisture either, but it does not dry the shop in winter. Dehumidification is a cooling-mode function. Its real constraint is the cold end: ENERGY STAR cold-climate units must hit COP at least 1.75 at 5°F and retain at least 70% of their 47°F capacity at 5°F. A unit sized to the shop's load at mild temperatures can be short on the design day. PickHVAC also notes a Cooper & Hunter 12,000 Btu single-zone at 9.5 HSPF and 19 SEER — but that's a 115V unit, not a cold-climate 240V machine, and it's a listing spec, not a lab test.

The Honest Compromise

If you want propane's fuel economics without the moisture and byproducts, name the category correctly: direct-vent. A sealed combustion appliance pulls air from outdoors and exhausts outdoors, per HVACLens citing Heat & Glo. The PickHVAC list includes the Martin direct-vent wall heater at 20,000 Btu and 77% efficiency and the Modine HD45AS0111 at 45,000 Btu, 80%, convertible to propane, roof or wall vented. You pay for the vent and lose some efficiency, and you stop dumping water in your shop.

One more shop-specific hazard PickHVAC raises about wood stoves: concerns about igniting flammable vapors or setting off a fire with sawdust in a working woodshop. That's their reasoning about stoves, not a tested finding about torpedo heaters, but the logic holds for anything with an open flame or exposed hot element in a dusty shop.

What I'd Actually Do

Size from a real load calc, not a guess about your door frame. Then price your own electricity and propane — the EIA tables are public and your bill is right there. Run the million-BTU math for your region, because the ranking genuinely flips. Then decide with your eyes open.

The 240V unit is the one you buy when you're already paying for the circuit anyway and you use it sporadically. The torpedo is the one you regret by February, both for the bill and for what it did to your steel. The mini-split costs the most up front and runs the cheapest, and it still loses capacity on the coldest day, so size for the design day rather than the catalog number. Direct-vent propane hides in the middle with no water in the shop and decent fuel economics.

Any of those three beats a vent-free torpedo on a rusted-up table saw. That's the decision, and it's not close.